3" Backflow Preventer, APOLLO 4ALF700E9 Reduced Pressure Detector Assembly, Lead-Free , Stainless Steel Body with Monitored Butterfly Valves, Grooved Ends
Part #00-4ALF700E9
MFG #4ALF700E9
Product Description
3" Backflow Preventer, Reduced Pressure Detector Assembly, Lead-Free, Stainless Steel Body with Monitored Butterfly Valves, Grooved Ends APOLLO 4ALF700E9
$3,941.48
- Brand: Apollo™End Style: GroovedNominal Size: 3 inOption: Lead-FreeType: Backflow - RPManufacturer Name: Aalberts Integrated Piping Systems
- Type 1, By-pass on right
- The 2 ½” – 12” Reduced Pressure Detector Assembly shall be an Apollo® Model RPDALF4A or RPDA2LF4A. The assembly shall be manufactured in America and carry a 5-year Apollo® factory warranty. The TriForceTM center-stem guided check valves shall feature reversible silicone rubber seat discs. The check valves shall be held in place by SS snap-in retainers (2 ½” – 6”) or SS studs & nuts (8” – 12”). Access to the check valves and relief valve internals shall be by an Apollo® quick-connect SS coupling (2 ½” – 6”) or grooved couplings (covers) and SS bolts (relief valves) (8” – 12”). The bodies shall be SS in 2 ½” – 8” sizes and FDA epoxy-coated ductile iron in 10” & 12” sizes. The assembly is a mainline RP with a Type 2 bypass consisting of a lead free* single check valve (SCV) and meter bypassing the mainline second check to prevent backflow while accurately measuring all flows up to 2 gpm with the mainline 2nd check remaining closed. Assemblies with the optional Type 1 bypass consist of a lead free* RP and meter which bypasses both mainline checks and accurately meters all flows up to 2 gpm with both mainline checks closed. The Apollo® domestic ball valve test cocks shall have SS handles. Both RP relief valves shall be positioned at the bottom of their respective assemblies with separate center-access covers. The pressure drop across the assembly shall be documented by an independent laboratory. The assembly shall prevent contamination of the potable water supply due to back-siphonage or back pressure from substances that are health or non-health hazards.
- Domestic Stainless steel body: 2 ½” – 8”
- FDA epoxy-coated ductile iron body: 10” & 12”
- Easy maintenance – no special tools required
- Snap-in check retainers: 2 ½” – 6”
- Bolted-in checks: 8” – 12”
- Low pressure loss as documented by an independent laboratory
- Center-stem guided TriForceTM check valves
- Approved for horizontal flow
- US Patents: 6,443,184; 7,025,085; 7,533,699; 8,240,333
- Made in the USA
- Maximum Working Pressure 175 psi
- Temperature Range 33 ° F – 140 ° F
- Hydrostatic Test Pressure 350 psi
- Approved by the Foundation for Cross-Connection Control and Hydraulic Research at the University of Southern California|ASSE 1048|CSA B.64.5|IAPMO Listed|FM Approved|USC FCCCHR|UL/cUL Listed|US Patents 6443184/7025085/7533699|NSF/ANSI 372|PROP65: Cancer and Reproductive Harm